Elenco Electronics AM-550TK Instruction Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
If an oscilloscope is not available, skip the following test and go directly to Section 2.
-13-
Output Adjust
V
Amps COM V/Ω
10μFGenerator
Figure 7
Battery
GND
R15
GND
R15
Connect the VOM and generator to TP6 as shown in
Figure 7.
Turn the power ON. Normally the AC gain is measured
at a frequency of 1 kilohertz (kHz). Your VOM, however,
may not be able to accurately read AC voltages at this
frequency. It is recommended, therefore, that this test
be performed at 400Hz. Set the generator at 400Hz and
minimum voltage output. Set your VOM to read an AC
voltage of 1 volt at the output of your Audio Amplifier.
Slowly increase the output of the generator until the
VOM reads 1 volt AC. Leave the audio at this setting
and move the positive lead of your VOM to TP6. Record
the AC voltage input to the amplifier here:
Vin=___________ volts.
You may have to change scales on your VOM for the
most accurate reading. Turn the power OFF. The AC
voltage gain of your Audio Amplifier is equal to the AC
output voltage divided by the AC input voltage, or 1/Vin.
Your calculated AC Gain should be approximately 10.
AC GAIN
Page view 13