Elenco Electronics M-1008K Instruction Manual

Browse online or download Instruction Manual for Multimeters Elenco Electronics M-1008K. Elenco Electronics M-1008K Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ELENCO
®
Copyright © 2012 by ELENCO
®
All rights reserved. 753014
No part of this book shall be reproduced by any means; electronic, photocopying, or otherwise without written permission from the publisher.
DIGITAL MULTIMETER KIT
MODEL M-1008K
Assembly and Instruction Manual
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - DIGITAL MULTIMETER KIT

ELENCO®Copyright © 2012 by ELENCO®All rights reserved. 753014No part of this book shall be reproduced by any means; electronic, photocopyi

Page 2 - PARTS LIST

DC AMPS TEST1) Set the range switch to 200μA and connect themeter as in Figure Q. With RA equal to 100kΩ thecurrent should be about 90μA. Compare ther

Page 3 - Warning:

-10-FINAL ASSEMBLYr Peel the backing off of the shield label and stick it onto the case bottom in the location shown in Figure Ra.r Snap the case bott

Page 4 - CONSTRUCTION

-11-THEORY OF OPERATIONFigure 1InputSelectorSwitchesACConverterOhmsConverterCurrentShuntVVΩIVoltageDividerSelectorSwitchesVA/DConverter& DisplayDr

Page 5 - ASSEMBLY INSTRUCTIONS

-12-The integrate period begins at the end of theautozero period. As the period begins, the AZ switchopens and the INTEG switch closes. This applies t

Page 6

-13-Figure 27106 IC FunctionsFigure 3ababcdefgTYPICAL SEGMENT OUTPUT0.5mA2mAV+SegmentOutputInternal Digital GroundLCD PHASE DRIVERLATCH7 SegmentDecode

Page 7

-14-DC VOLTAGE MEASUREMENTFigure 4 shows a simplified diagram of the DC voltagemeasurement function. The input voltage divider resistorsadd up to 1 me

Page 8 - Figure M

DIODE CHECKRANGE RESOLUTION MAX TEST CURRENT MAX OPEN CIRCUIT VOLTAGEDIODE 1mV 1.4mA 2.8VTRANSISTOR hFETESTRANGE TEST RANGE TEST CURRENT TEST VOLTAGEN

Page 9 - If the calibration fails:

-16-METER OPERATIONPRECAUTIONS AND PREPARATIONS FOR MEASUREMENT1) Be sure the battery is connected to the batterysnap and correctly placed in the batt

Page 10 - If any of these tests fail:

-17-DIODE CHECK1) Connect the black test lead to the “COM”terminal.2) Connect the red test lead to the “VΩmA” terminal.3) If the diode being measured

Page 11 - FINAL ASSEMBLY

-18-Answers to Quiz: 1. C, 2. D, 3. B,4. A, 5. D, 6. A, 7. B, 8. C, 9. B, 10. BSCHEMATIC DIAGRAM

Page 12 - THEORY OF OPERATION

PARTS LISTIf you are a student, and any parts are missing or damaged, please see instructor or bookstore. If you purchased this meterkit from a distri

Page 13 - IN / VREF)

ELENCO®150 Carpenter AvenueWheeling, IL 60090(847) 541-3800Website: www.elenco.come-mail: [email protected]

Page 14 - Figure 3

-2-IDENTIFYING RESISTOR VALUESUse the following information as a guide in properly identifying the value of resistors.5 Bands1 2MultiplierTolerancePAR

Page 15

-3-CONSTRUCTIONSolderSoldering IronFoilSolderSoldering IronFoilComponent LeadSoldering IronCircuit BoardFoilRosinSoldering iron positionedincorrectly.

Page 16 - SPECIFICATIONS

ASSEMBLY INSTRUCTIONSIdentify and install the following parts as shown. After soldering each part, mark a check þ in the box provided.Be sure that sol

Page 17 - METER OPERATION

Install the following parts. Then, mark a check þ in the box provided.-5-ASSEMBLY INSTRUCTIONSIdentify and install the following parts as shown. After

Page 18

-6-Figure FTa bInput socketsShunt wireRed wireBlack wireSolderBattery snapTransistor socketFuse clipsClear protective filmFigure LSpring holes4mm Spri

Page 19 - SCHEMATIC DIAGRAM

r Put the ball bearings into two opposite indents inthe case top as shown in Figure M.r Place the six slide contacts on the selector knobsas shown.r P

Page 20

1) ACV Range: 600 HV 0 0 0200 0 0.02) DCA,10A Ranges: 200μ 0 0.02,000μ 0 0 020m 0.0 0200m 0 0.010A 0.0 03) Ohms, Diode and hFE Ranges: B indicates b

Comments to this Manuals

No comments